Use este identificador para citar ou linkar para este item: http://repositorio.utfpr.edu.br/jspui/handle/1/1843
Título: Galvanic vestibular stimulator for fMRI research
Título(s) alternativo(s): Estimulador galvânico vestibular para experimentos de fMRI
Autor(es): Rülander, Britta Angela
Orientador(es): Gamba, Humberto Remigio
Palavras-chave: Aparelho vestibular
Imagem de ressonância magnética
Processamento de imagens - Técnicas digitais
Circuitos integrados
Interface gráfica com o usuário (Sistemas de computação)
Métodos de simulação
Engenharia biomédica
Engenharia elétrica
Vestibular apparatus
Magnetic resonance imaging
Image processing - Digital techniques
Integrated circuits
Graphical user interfaces (Computer systems)
Simulation methods
Biomedical engineering
Electric engineering
Data do documento: 2-Mar-2016
Editor: Universidade Tecnológica Federal do Paraná
Câmpus: Curitiba
Citação: RÜLANDER, Britta Angela. Galvanic vestibular stimulator for fMRI research. 2016. 90 f. Dissertação (Mestrado em Engenharia Elétrica e Informática Industrial) - Universidade Tecnológica Federal do Paraná, Curitiba, 2016.
Abstract: This master thesis presents the further development of a galvanic vestibular stimulator for use in fMRI examinations developed in a previous thesis (MANCZAK, 2012). This thesis amends the GVS by circuits to measure feedback values and implements the stimulation circuit with digital components, such as a microcontroller and flyback integrated circuits. The microcontroller is used in order to control the current source and process the measured values. The communication between the PC, which allows user interaction through a graphical user interface, and the microcontroller is implemented through optical communication, which is defined by a communication protocol specification. The digital circuitry is designed to be placed within the MRI room, meeting the requirements imposed by strong magnetic fields and radio frequency pulses. The underlying hypothesis of the thesis is that the device can be placed within the MRI room without having a negative impact on the MRI image quality. Laboratory tests without the MRI confirmed the correct design of the galvanic vestibular stimulator.
URI: http://repositorio.utfpr.edu.br/jspui/handle/1/1843
Aparece nas coleções:CT - Programa de Pós-Graduação em Engenharia Elétrica e Informática Industrial

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
CT_CPGEI_M_Rülander, Britta Angela_2016.pdf6,43 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.