Use este identificador para citar ou linkar para este item: http://repositorio.utfpr.edu.br/jspui/handle/1/816
Registro completo de metadados
Campo DCValorIdioma
dc.creatorOliveira, Paulo Henrique de-
dc.date.accessioned2014-05-06T13:49:49Z-
dc.date.issued2012-04-27-
dc.identifier.citationOLIVEIRA, Paulo Henrique de. A versatile current source for low, middle frequencies and interferential pulse therapies. 2012. 116 f. Dissertação (Mestrado em Engenharia Elétrica e Informática Industrial) – Universidade Tecnológica Federal do Paraná, Curitiba, 2012.pt_BR
dc.identifier.urihttp://repositorio.utfpr.edu.br/jspui/handle/1/816-
dc.description.abstractElektrostimulation ist ein wichiges Hilfsmittel in der Medizin mit Anwendungen im Bereich der Muskelrehabilitation, der Schmerztherapie und in Herzschrittmachrn. Tragbare Stimulatoren zum hauslichen Gebrauch warden hauptsachlich in zwei Gruppen unterteit: Niederfrequenz- und Mittelfrequenztherapiegerate. Bisher gibt es in Deutschland kein Great das beide Therapieformen durchfuhren kann, sodas das Hauptziel dieses Projekts die Entwicklung einer Stromquelle ist, die in der Lage ist, beide Therapieformen anzuwender. Das Great ist zusatzlich in der Lage beiebige, einstellbare Stimulationsmuster zu erzeugen, welche durch einen externen Mikrocontroller gesteuent warden. Auberdem soll disses System Interferenzstromtherapie ermoglichen. Das Ergebnis dieses Projekts ist ein elektronisches Great, das auf drei Steuersignalen basierende Reizstrommuster erzeugt. Diese Steuersignale konnen von einem Mikrocontroller einfach generiert warden. Das System ermoglicht NF-Stimulation mit ausbalancierten Stromimpulsen bis zu 80mA bei 1K? Lastimpedanz, Pulsbreiten zwischen 50 und 1000us und Frequezen bis 150Hz. Es beinhaltet MF-Stimulationsausgange fur bis zu 100mApp Ausgangsstrom, mit Modulationsfrequenzen bis zu 4k Hz und einem einfachen Interface zur Steuerung der Wellenform der Hullkurve. Es bietet zwei galvanische getrennte Kanale zur Interferenzstromtherapie. Falls Kein Ausgangsstrom benotgt wind, konnen die Ausgange Kurzeschlossen warden, um den korper des Patienten vo einer moglichen elektrischen Aufladung das Gerate zu schutzen. Daruber hinaus wurden eine MATLAB application und eine SPICE Simulation entwickelt, um die Erstellung von Steuersignalen zu unterstutzen. Das System Kann beliebige Reiztrommuster erzengen, dadurch eignet es zur Erforschung der optimalen Impulswellenformen vieler verschiedener Elektrotherapien.pt_BR
dc.languageengpt_BR
dc.publisherUniversidade Tecnológica Federal do Paranápt_BR
dc.subjectEstimulação elétrica transcutânea do nervopt_BR
dc.subjectEletroterapiapt_BR
dc.subjectEngenharia biomédicapt_BR
dc.subjectEngenharia elétricapt_BR
dc.subjectTranscutaneous electrical nerve stimulationpt_BR
dc.subjectElectrotherapeuticspt_BR
dc.subjectBiomedical engineeringpt_BR
dc.subjectElectric engineeringpt_BR
dc.titleA versatile current source for low, middle frequencies and interferential pulse therapiespt_BR
dc.typemasterThesispt_BR
dc.description.resumoElectrical stimulation is an important tool in medicine with applications like muscle rehabilitation, pain management and pacemakers. Portable stimulation devices for home use are divided mainly in two domains: low and middle frequency therapies. Due to the lack, in Germany, of a system to provide both therapies at the same equipment, the main objective of this project is the development of a current source not only capable of that, but also able to generate arbitrary stimulation patterns controlled by an external microcontroller. Moreover, the system should make possible the use of interferential current therapy. The result of the project is an electronic device that triggers current stimulation patterns based on three control signals, which could be easily generated by a microcontroller. The system provides LF stimulation with balanced current pulses up to 80mA through 1k? load impedance, pulse widths between 50 and 1000µs, and frequencies up to 150Hz. It also provides MF stimulation outputs up to 100mApp, with a modulation frequency up to 4kHz and a simple interface to control the envelope waveform. It presents also two galvanic isolated channels to allow interferential current therapy and, when no output current is intended, it is able to provide a short circuit on the load to remove possible net charges introduced by the system to the patient’s body. Additionally, a MATLAB application and a SPICE simulation were developed to assist the creation of control signals. As the system is able to deliver stimulation currents with an arbitrary pattern, it can be used to find the best pulse waveforms for a series of different applications involving electrical therapy, like TENS and MES.pt_BR
dc.description.embargo5000-
dc.degree.localCuritibapt_BR
dc.degree.levelMestradopt_BR
dc.publisher.localCuritibapt_BR
dc.contributor.advisor1Gamba, Humberto Remigio-
dc.contributor.advisor-co1Nguyen, Phuc-
dc.contributor.advisor-co1Zwick, Albrecht-
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétrica e Informática Industrialpt_BR
Aparece nas coleções:CT - Programa de Pós-Graduação em Engenharia Elétrica e Informática Industrial

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
CT_CPGEI_M_Oliveira, Paulo Henrique de_2012.pdf
  Acesso Restrito
3,45 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.