Título: Analysis of the fire effect on loadbearing LSF walls and design of experimental test setup
Autor(es): Garbin, Carlos Henrique Cano
Orientador(es): Piloto, Paulo Alexandre Gonçalves
Palavras-chave: Aço - Estruturas
Paredes
Método dos elementos finitos
Fogo
Materiais de construção - Testes
Steel, Structural
Walls
Finite element method
Fire
Building materials - Testing
Data do documento: 14-Dez-2020
Editor: Universidade Tecnológica Federal do Paraná
Câmpus: Campo Mourao
Citação: GARBIN, Carlos Henrique Cano. Analysis of the fire effect on loadbearing LSF walls and design of experimental test setup. 2020. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) - Universidade Tecnológica Federal do Paraná, Campo Mourão, 2020.
Resumo: Este trabalho apresenta um estudo do comportamento ao fogo de paredes portantes de LSF. Este estudo foi feito com o desenvolvimento de modelo em elementos finitos e análise paramétrica para avaliar os efeitos da seção de aço e da espessura da placa de gesso na resistência ao fogo. Também foi projetada a configuração do teste experimental para futuras pesquisas experimentais nas instalações do IPB. O modelo foi desenvolvido com a utilização de elementos de casca para a estrutura de aço e elementos sólidos para as placas. Foram feitas simulações mecânicas, térmicas e termomecânicas, que foram validadas com a utilização de resultados de testes experimentais realizados anteriormente na Universidade de Queensland. A análise paramétrica demonstrou que a espessura da placa de gesso teve pouco efeito no comportamento ao fogo da parede, cerca de 3,5% de aumento na evolução da temperatura, o que pode ser explicado pelo painel compósito utilizado. A espessura da seção de aço no entanto apresentou maior influência, 58,15% do aumento da capacidade de carga da parede.
Abstract: This work present a study of the fire behaviour of loadbearing LSF walls. This study was made with the development of model in finite elements and parametric analysis to evaluete the effects of steel section and plasterboard thickness on the fire resistance. It was also design the experimental test setup for future experimental researchs in IPB facilities. The model was developed with the use of shell elements for the steel structure and solid elements for the boards. It was made mechanic, termal and termo-mechanic simulations, that were validated with the use of experimental tests results previous realized in University of Queensland. The parametric analysis demostrated that the plasterboard thickness was of little effect in the fire behaviour of the wall, close to 3.5% of increase in the temperature evolution, what can be explained by the composite panel utilized. The steel section thickness however presented a greater influence, 58.15% of increase of the loadbeaing capacity of the wall.
Descrição: O presente trabalho é resultado de um convênio de dupla diplomação com o Instituto Politécnico de Bragança (Portugal).
URI: http://repositorio.utfpr.edu.br/jspui/handle/1/32463
Aparece nas coleções:CM - Engenharia Civil

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
analysisfireeffectloadbearing.pdf2,03 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.