Título: Condições de estresse e conforto térmico em fábrica de pré-moldado em Ponta Grossa - PR
Título(s) alternativo(s): Conditions of heat stress and thermal comfort in precast industry in Ponta Grossa - PR
Autor(es): Galvan, Tanise Fuckner de Oliveira
Orientador(es): Xavier, Antonio Augusto de Paula
Palavras-chave: Concreto pré-moldado
Ambiente de trabalho
Conforto humano
Temperatura atmosférica - Efeito fisiológico
Engenharia civil
Precast concrete
Work environment
Human comfort
Atmospheric temperature - Physiological effect
Civil engineering
Data do documento: 28-Fev-2018
Editor: Universidade Tecnológica Federal do Paraná
Câmpus: Ponta Grossa
Citação: GALVAN, Tanise Fuckner de Oliveira. Condições de estresse e conforto térmico em fábrica de pré-moldado em Ponta Grossa - PR. 2018. 89 f. Dissertação (Mestrado em Engenharia de Produção) - Universidade Tecnológica Federal do Paraná, Ponta Grossa, 2018.
Resumo: O estresse térmico é um risco reconhecido a que os trabalhadores de várias indústrias estão expostos. De forma a verificar a condição de estresse e também conforto térmico na fábrica de pré-moldado em concreto, foi realizada uma pesquisa na qual as variáveis ambientais e pessoais foram obtidas através de medições e questionários. A avaliação preliminar do estresse térmico foi realizada pela escala HSSI, a qual indicou a não existência do mesmo nessa fábrica. Foi efetuada a avaliação do ambiente, através dos índices IBUTG e PHS, que ratificaram a não existência do estresse térmico. Como não houve a incidência do estresse térmico, o ambiente foi avaliado com relação ao conforto térmico, nas medições em que o índice PMV era aplicável, e foi calculado o índice PET. Através do cálculo do índice do PMV, verificou-se que em apenas uma medição o ambiente pode ser considerado confortável, nas demais o ambiente é considerado desconfortável termicamente. Os resultados do índice PET, demonstram que na maioria das medições também ficou caracterizada o desconforto térmico.
Abstract: Heat stress is a recognized risk that workers in various industries are exposed. In order to verify the stress condition and also thermal comfort in the precast concrete factory, a research was carried out in which the environmental and personal variables were obtained through measurements and questionnaires. The preliminary evaluation of the heat stress was performed by the HSSI scale, which indicated the absence of heat stress in this factory. To confirm this conclusion, the evaluation of the environment was carried out through the IBUTG and PHS indices, which confirmed the absence of heat stress. As there was no incidence of heat stress, the environment was evaluated with respect to thermal comfort, in the measurements in which the PMV index was applicable and the PET index was calculated. Through the calculation of the PMV index, it was verified that in only one measurement the environment can be considered comfortable, in the others the environment is considered to be thermally uncomfortable. Through the calculation of the PMV index, it was verified that in only one measurement the environment can be considered comfortable, in the others the environment is considered to be thermally uncomfortable. The results of the PET index show that thermal discomfort was also characterized in most of the measurements.
URI: http://repositorio.utfpr.edu.br/jspui/handle/1/3106
Aparece nas coleções:PG - Programa de Pós-Graduação em Engenharia de Produção

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
PG_PPGEP_M_Galvan, Tanise Fuckner de Oliveira_2018.pdf2,1 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.